CR Magnetics CR4395-LH-120-110-A-CD-ELR-I Current Sensing Relay with Internal Transformer, 120 VAC, Latch on High Trip, 1 - 10 AAC Trip Range, 0.5 - 6 Second Trip on Delay
CR Magnetics CR4395-LH-120-110-A-CD-ELR-I Current Sensing Relay with Internal Transformer, 120 VAC, Latch on High Trip, 1 - 10 AAC Trip Range, 0.5 - 6 Second Trip on Delay
  • Current sensing relay for monitoring electrical current
  • Current carrying wire is routed through an aperture
  • Electrical isolation between circuits (SPDT)
  • Internal transformer for scaling the current and a voltage reference circuit for a repeatable trip point
  • UL Recognized for safety and RoHS compliant for hazardous substances
size:
  • 1-10 AAC Trip Range, 0.5-6 Second Trip on Delay
Retail Price: $ 88.79
Wholesale Price: Inquire Now
...
CR Magnetics CR4395-LH-120-110-A-CD-ELR-I Current Sensing Relay with Internal Transformer, 120 VAC, Latch on High Trip, 1 - 10 AAC Trip Range, 0.5 - 6 Second Trip on Delay
CR Magnetics CR4395-LH-120-110-A-CD-ELR-I Current Sensing Relay with Internal Transformer, 120 VAC, Latch on High Trip, 1 - 10 AAC Trip Range, 0.5 - 6 Second Trip on Delay

BEST SELLERS

...
This CR Magnetics CR4395 current sensing relay has an internal transformer, requires a supply voltage of 120 VAC, latches on high trip, and is used for monitoring electrical current in power supply applications. This current sensing relay has a window for routing the current-carrying wire and a calibrated dial for setting the trip point. An adjustable delay-on timer provides stability. When the current rises above the set trip point, the relay is tripped and starts the timer. After the timer cycles, the relay is energized and turns the output to full on. The relay remains tripped (latched) until the supply of power is removed. It has an internal transformer for scaling the current up or down and a voltage reference circuit that provides a repeatable trip point. This relay is Underwriters Laboratories (UL) Recognized for safety and is Restriction of Hazardous Substances (RoHS) compliant. This current sensing relay has an LED indicator that alerts the user when the relay is tripped and is suitable for monitoring electric heater elements, sensing motor over/under loads, detecting lamp burn-out, and indicating phase-loss.

This CR Magnetics CR4395 current sensing relay has an internal transformer, requires a supply voltage of 120 VAC, latches on high trip, and is used for monitoring electrical current in power supply applications. This current sensing relay has a window for routing the current-carrying wire and a calibrated dial for setting the trip point. An adjustable delay-on timer provides stability. When the current rises above the set trip point, the relay is tripped and starts the timer. After the timer cycles, the relay is energized and turns the output to full on. The relay remains tripped (latched) until the supply of power is removed. It has an internal transformer for scaling the current up or down and a voltage reference circuit that provides a repeatable trip point. This relay is Underwriters Laboratories (UL) Recognized for safety and is Restriction of Hazardous Substances (RoHS) compliant. This current sensing relay has an LED indicator that alerts the user when the relay is tripped and is suitable for monitoring electric heater elements, sensing motor over/under loads, detecting lamp burn-out, and indicating phase-loss.

Specifications

Contact form1 Form C (SPDT)
Contact materialSilver-cadmium oxide
Supply voltage120VAC
Power-on delay100 ms maximum
Input supply power80 mA normal; 100 mA maximum
Rated output20 amps maximum
Maximum sensed currentContinuous 200% full scale
Hysteresis5% maximum
Mechanical life10 million operations at normal rated load
Electrical life100,000 operations at normal rated load
Initial contact resistance50 milliohms maximum at 500 mA, 12VDC
Frequency (at 60 Hz)60 to 400 Hz
Operating temperature-30 to +60 degrees C
Storage temperature-55 to +85 degrees C
Terminals3-1/4" male QC (quick connect)
Enclosure Dimensions2-1/8 x 3-1/2 x 2-1/2 inches (H x W x D)
Standards metUL Recognized
RoHS compliant

*H is height, the vertical distance from the lowest to highest point; W is width, the horizontal distance from left to right; D is depth; the horizontal distance from front to back.

Relay switches (also called an electrical relay or an electrical relay switch) use a small amount of power to control a larger source of power connected to electrical devices such as car motors, computers, and lighting installations. A basic relay switch has a control circuit with an electromagnetic coil and a load circuit with contacts and a lever. When current flows into the relay switch, it moves through the coil and a magnetic field is created, which causes the lever in the load circuit to move between contacts, either turning the device on or off. In a normally open (NO) relay switch, when power is supplied to the relay, the load circuit is closed and the power source connected to the relay is turned on. In a normally closed (NC) relay switch, when power is supplied to the relay, the load circuit is open and the power source connected to the relay is turned off. In other types of relay switches, non-moving parts such as transistors or semiconductors can be used as the control circuit to operate the switching mechanism. Relay switches can be controlled with an external switch, such as a light switch, or they can be connected to an automatically switched power source, such as a car ignition. One relay can operate multiple switches, and multiple relays can be operated with a single switch, with each relay operating independently from the other relays in the system.

CR Magnetics manufactures electrical sensors, indicators, and displays. The company, founded in 2004, is headquartered in Saint Louis, MO.

Shipping Notices:
1 Contraband and limited items:
Clgarette,Alcohol,Contraband ?Do not accept
... ... ...
Liquid,cream or cosmetics items are quantity limited in shopping agent service
... ... ...
Chinese medicine is limited to ship by Chinese exporting goods.
...
2 Limitation for different shipping methods:
...
3 Yoybuy Product's Label:
...
Sensitive Product(SEN)
...
Product With battery
...
Cream
...
Powder
...
Dangerous Products
...
....
4 Volume weight Requested:
...
volume weight=length*height*Width/5000
...
one side must be less than 120cm,otherwise there is additional fee;250cm products can not be accept;
...
...
...
...
...
Any side must be less than 60cm,otherwise you will be charged the greater one between real weight and volume weight,more than 120cm will be not accepted.
After Sale Service:
2 The rules apply and summit for receive compensation
3 The conditions of accrual for amount insurance
3 The conditions of accrual for amount insurance
5 Damage to the parcel during international shipping, which resulted in damage to the goods in it
6 Loss of individual goods under international shipment The absence individual goods in the parcel
7 Non-compliance individual goods in color, size, complications Damage to the goods during international shipment
...

BEST SELLERS

Inquire Now
X

Contact us now

Language

Currency

    Upload image to find the same item

    Drag the image here, or Click to upload Tips: Only jpg, jpeg, png, webp

    Scan the QR code and use your phone to take a direct photo search.

    ×