EPEVER MPPT Charge Controller 20A 12v 24v Auto, Solar Panel Regulator 100V PV Negative Grounded Solar Controller fit for Gel Sealed Flooded and Lithium Battery
EPEVER MPPT Charge Controller 20A 12v 24v Auto, Solar Panel Regulator 100V PV Negative Grounded Solar Controller fit for Gel Sealed Flooded and Lithium Battery
size:
  • 2210AN+MT50+TS-R+RS485
Retail Price: $ 122.99
Wholesale Price: Inquire Now

Specification:

  • Multiple load control modes: manual control, lighting ON/OFF, light On+Timer
  • Advanced Maximum Power Point Tracking (MPPT) technology, with efficiency no less than 99.5%
  • Wide MPPT operating voltage range
  • LCD display design, dynamically displaying tool's operating data and working condition
  • Available for PC monitoring and external display realizing real-time data checking and parameters setting

Added Features(than Tracer A):

  • Blacklight LCD Display / Common Negative Ground / Support lithium Battery / More Safety Protection

MT-50:

  • Compatible with EPever Tracer-A/AN/BN, LS-B/BP, VS-BN series controllers
  • Automatic identify the controller, and display the type, model and relevant parameter data
  • Large-screen multifunction LCD displays all the operational data and system working status
  • Real-time energy statistics recording
  • Longer communication distance based on RS485
  • Diversified load control modes:manual, light ON/OFF, Light ON+ Timer, Time Control

Package List:

1 x Tracer 2210AN Solar Charge Controller

1 x MT-50, 1 x Temp sensor,

2 x Use Manual

2210

Tracer AN MPPT Charge Controller Features:

  • 12 / 24VDC Auto
  • Rated charge current: 20A
  • Max Input Power:12V@ 260W | 24V@ 520W
  • Max PV open circuit voltage:100VDC (92V at 25℃ temperature)
  • Battery type selection: lead-acid (Gel, Sealed, Flooded) and Lithium
  • Charging Power and Current Limitation Function
  • User programmable for battery types, load control etc.
  • Accurately recognizing and tracking of multiple power point
  • PV short circuit / PV reverse polarity /Battery over voltage
  • Battery over discharge / Battery reverse polarity / Load overload protection
  • You can connect two or more Tracer charge controller to the batteries bank in parallel, but do not share PV Panels. Dedicate a number of PV panels to each mppt controller.
  • Never connect the soalr panel array to the controller Without/Before a Battery.
2

Warm tips:

Step: Connect the system in the order of 1.battery-->2. load-->3.PV array, and disconnect the system in the reverse order 3. 2. 1.

  • Never connect the soalr panel array to the controller Without/Before a Battery.
  • Battery must be connected first !!!
  • DO NOT connect any inverter/ wind/Alternator or Charger into the charge controller!
  • If the remote temperature sensor is not connected to the controller,, the default setting for battery charging or discharging temperature is 25 °C without temperature compensation.
  • The wire size is only for reference. If there is a long distance between the PV array and the controller or between the controller and the battery, larger wires can be used to reduce the voltage drop and improve performance.

How to program for Lithium Battery?

1. Via PC (Accessories needed:RS485), software download website: EPever official website or look for in the manual

2. Via lastest Andriod phone APP (Accessories needed:Ebox-Wifi or Ebox-Blue)

2 4219 5 6 3 3
Tracer 2210AN Controller Tracer 4210AN Controller Tracer 5415AN Controller Tracer 6415AN Controller Tracer 3210AN Controller MPPT Controller 30A
System Voltage 12V/24V DC 12V/24V DC 12V/24V/36V/48V DC 12V/24V/36V/48V DC 12V/24V/ DC 12V/24V DC
Max Power Current 20A 40A 50A 60A 30A 30A
Max Input Power 12V/260W | 24V/520W 12V/520W | 24V/1040W 12V/625W | 24V/1250W 36V/1875W | 48V/2500W 12V/750W | 24V/1500W 36V/2250W | 48V/3000W 12V@ 390W | 24V@ 780W 12V@ 390W | 24V@ 780W
Max,PV Open Circuit Voltage 100V(92V At 25℃ temperature) 100V(92V At 25℃ temperature) 150V(138V At 25℃ temperature) 150V(138V At 25℃ temperature) 100V(92V At 25℃ temperature) 150V(138V At 25℃ temperature)
Grounding Negative Negative Negative Negative Negative Negative
Battery Type Sealed, Gel and Flooded, User and Lithium Sealed, Gel and Flooded, User and Lithium Sealed, Gel and Flooded and User Sealed, Gel and Flooded and User Sealed, Gel and Flooded, User and Lithium Sealed, AGM, Gel. Flooded and User
1 5 3 3 4 4
RS485-150U+TS-R MT50 meters MC4 Connectors 10 Pairs 30A charge controller 45A charge controller 60A charge controller
Support Tracer A/AN/BN Controller Fit for Tracer A/AN/BN Mppt controller 5 Pair/ 10 Pair/ 20 Pair Fit for Lead-acid Battery Fit for Lead-acid Battery Fit for Lead-acid Battery
This website follows the safe harbor principle. If any infringement, please inform us in time and we will delete it in time. About safe harbor,please click here to learn more.
...
After Sale Service:
1 Insurance Policy: Click to go to the Help Center to view the Insurance Policy
2 The rules apply and summit for receive compensation
3 The conditions of accrual for amount insurance
3 The conditions of accrual for amount insurance
5 Damage to the parcel during international shipping, which resulted in damage to the goods in it
6 Loss of individual goods under international shipment The absence individual goods in the parcel
7 Non-compliance individual goods in color, size, complications Damage to the goods during international shipment
8 Returns Policy: Click to go to the Help Center to view the Returns Policy
...
...
EPEVER MPPT Charge Controller 20A 12v 24v Auto, Solar Panel Regulator 100V PV Negative Grounded Solar Controller fit for Gel Sealed Flooded and Lithium Battery
EPEVER MPPT Charge Controller 20A 12v 24v Auto, Solar Panel Regulator 100V PV Negative Grounded Solar Controller fit for Gel Sealed Flooded and Lithium Battery

BEST SELLERS

...

Product Description

Specification:

  • Multiple load control modes: manual control, lighting ON/OFF, light On+Timer
  • Advanced Maximum Power Point Tracking (MPPT) technology, with efficiency no less than 99.5%
  • Wide MPPT operating voltage range
  • LCD display design, dynamically displaying tool's operating data and working condition
  • Available for PC monitoring and external display realizing real-time data checking and parameters setting

Added Features(than Tracer A):

  • Blacklight LCD Display / Common Negative Ground / Support lithium Battery / More Safety Protection

MT-50:

  • Compatible with EPever Tracer-A/AN/BN, LS-B/BP, VS-BN series controllers
  • Automatic identify the controller, and display the type, model and relevant parameter data
  • Large-screen multifunction LCD displays all the operational data and system working status
  • Real-time energy statistics recording
  • Longer communication distance based on RS485
  • Diversified load control modes:manual, light ON/OFF, Light ON+ Timer, Time Control

Package List:

1 x Tracer 2210AN Solar Charge Controller

1 x MT-50, 1 x Temp sensor,

2 x Use Manual

2210

Tracer AN MPPT Charge Controller Features:

  • 12 / 24VDC Auto
  • Rated charge current: 20A
  • Max Input Power:12V@ 260W | 24V@ 520W
  • Max PV open circuit voltage:100VDC (92V at 25℃ temperature)
  • Battery type selection: lead-acid (Gel, Sealed, Flooded) and Lithium
  • Charging Power and Current Limitation Function
  • User programmable for battery types, load control etc.
  • Accurately recognizing and tracking of multiple power point
  • PV short circuit / PV reverse polarity /Battery over voltage
  • Battery over discharge / Battery reverse polarity / Load overload protection
  • You can connect two or more Tracer charge controller to the batteries bank in parallel, but do not share PV Panels. Dedicate a number of PV panels to each mppt controller.
  • Never connect the soalr panel array to the controller Without/Before a Battery.
2

Warm tips:

Step: Connect the system in the order of 1.battery-->2. load-->3.PV array, and disconnect the system in the reverse order 3. 2. 1.

  • Never connect the soalr panel array to the controller Without/Before a Battery.
  • Battery must be connected first !!!
  • DO NOT connect any inverter/ wind/Alternator or Charger into the charge controller!
  • If the remote temperature sensor is not connected to the controller,, the default setting for battery charging or discharging temperature is 25 °C without temperature compensation.
  • The wire size is only for reference. If there is a long distance between the PV array and the controller or between the controller and the battery, larger wires can be used to reduce the voltage drop and improve performance.

How to program for Lithium Battery?

1. Via PC (Accessories needed:RS485), software download website: EPever official website or look for in the manual

2. Via lastest Andriod phone APP (Accessories needed:Ebox-Wifi or Ebox-Blue)

2 4219 5 6 3 3
Tracer 2210AN Controller Tracer 4210AN Controller Tracer 5415AN Controller Tracer 6415AN Controller Tracer 3210AN Controller MPPT Controller 30A
System Voltage 12V/24V DC 12V/24V DC 12V/24V/36V/48V DC 12V/24V/36V/48V DC 12V/24V/ DC 12V/24V DC
Max Power Current 20A 40A 50A 60A 30A 30A
Max Input Power 12V/260W | 24V/520W 12V/520W | 24V/1040W 12V/625W | 24V/1250W 36V/1875W | 48V/2500W 12V/750W | 24V/1500W 36V/2250W | 48V/3000W 12V@ 390W | 24V@ 780W 12V@ 390W | 24V@ 780W
Max,PV Open Circuit Voltage 100V(92V At 25℃ temperature) 100V(92V At 25℃ temperature) 150V(138V At 25℃ temperature) 150V(138V At 25℃ temperature) 100V(92V At 25℃ temperature) 150V(138V At 25℃ temperature)
Grounding Negative Negative Negative Negative Negative Negative
Battery Type Sealed, Gel and Flooded, User and Lithium Sealed, Gel and Flooded, User and Lithium Sealed, Gel and Flooded and User Sealed, Gel and Flooded and User Sealed, Gel and Flooded, User and Lithium Sealed, AGM, Gel. Flooded and User
1 5 3 3 4 4
RS485-150U+TS-R MT50 meters MC4 Connectors 10 Pairs 30A charge controller 45A charge controller 60A charge controller
Support Tracer A/AN/BN Controller Fit for Tracer A/AN/BN Mppt controller 5 Pair/ 10 Pair/ 20 Pair Fit for Lead-acid Battery Fit for Lead-acid Battery Fit for Lead-acid Battery
Shipping Notices:
1 Contraband and limited items:
Clgarette,Alcohol,Contraband ?Do not accept
... ... ...
Liquid,cream or cosmetics items are quantity limited in shopping agent service
... ... ...
Chinese medicine is limited to ship by Chinese exporting goods.
...
2 Limitation for different shipping methods:
...
3 Yoybuy Product's Label:
...
Sensitive Product(SEN)
...
Product With battery
...
Cream
...
Powder
...
Dangerous Products
...
....
4 Volume weight Requested:
...
volume weight=length*height*Width/5000
...
one side must be less than 120cm,otherwise there is additional fee;250cm products can not be accept;
...
...
...
...
...
Any side must be less than 60cm,otherwise you will be charged the greater one between real weight and volume weight,more than 120cm will be not accepted.
After Sale Service:
2 The rules apply and summit for receive compensation
3 The conditions of accrual for amount insurance
3 The conditions of accrual for amount insurance
5 Damage to the parcel during international shipping, which resulted in damage to the goods in it
6 Loss of individual goods under international shipment The absence individual goods in the parcel
7 Non-compliance individual goods in color, size, complications Damage to the goods during international shipment
...

BEST SELLERS

Inquire Now
X

Contact us now

Language

Currency

    Upload image to find the same item

    Drag the image here, or Click to upload Tips: Only jpg, jpeg, png, webp

    Scan the QR code and use your phone to take a direct photo search.

    ×