Gravity: Analog pH Sensor/Meter Kit V2 for Arduino - for Aquaponics Or Fish Tanks Or Other Materials That Need Measurements
Gravity: Analog pH Sensor/Meter Kit V2 for Arduino - for Aquaponics Or Fish Tanks Or Other Materials That Need Measurements
  • DFRobot Gravity: Analog pH meter V2 is specifically designed to measure the pH of the solution and reflect the acidity or alkalinity
  • This new Arduino Analog pH sensor/Meter is compatible with Raspberry Pi and Arduino microcontroller
  • Hardware filtered output signal, low jitter. Gravity connector and BNC connector, plug and play, no welding
  • Software library supports two-point calibration, and automatically identifies standard buffer solution
  • Uniform size and connector, convenient for the design of mechanical structures. More details and tutorial please visit dfrobot wiki>>> https://www.dfrobot.com/wiki/index.php/Gravity:_Analog_pH_Sensor/Meter_Kit_V2_SKU:SEN0161-V2
Retail Price: $ 45.5
Wholesale Price: Inquire Now

INTRODUCTION

  • DFRobot Gravity: Analog pH meter V2 is specifically designed to measure the pH of the solution and reflect the acidity or alkalinity.
  • It is commonly used in various applications such as aquaponics, aquaculture, and environmental water testing.

BACKGROUNDS

  • The pH is a value that measures the acidity or alkalinity of the solution. It is also called the hydrogen ion concentration index. The pH is a scale of hydrogen ion activity in solution. The pH has a wide range of uses in medicine, chemistry, and agriculture.
  • Usually, the pH is a number between 0 to 14. Under the thermodynamic standard conditions, pH=7, which means the solution is neutral; pH<7, which means the solution is acidic; pH>7, which means the solution is alkaline.

Gravity: Analog pH Sensor/Meter Kit V2

Gravity: Analog pH Sensor/Meter Kit V2

Attention

  1. The BNC connector and the signal conversion board must be kept dry and clean, otherwise, it will affect the input impedance, resulting in an inaccurate measurement. If it is damp, it needs to be dried.
  2. The signal conversion board cannot be directly placed on a wet or semiconductor surface, otherwise, it will affect the input impedance, resulting in the inaccurate measurement. It is recommended to use the nylon pillar to fix the signal conversion board, allow a certain distance between the signal conversion board and the surface.
  3. The sensitive glass bubble in the head of the pH probe should avoid touching with the hard material. Any damage or scratches will cause the electrode to fail.
  4. After completing the measurement, disconnect the pH probe from the signal conversion board. The pH probe should not be connected to the signal conversion board without the power supply for a long time.

SPECIFICATION-Signal Conversion Board (Transmitter) V2

Supply Voltage 3.3~5.5V
Output Voltage 0~3.0V
Probe Connector BNC
Signal Connector PH2.0-3P
Measurement Accuracy ±0.1@25℃
Dimension 42mm*32mm/1.66*1.26in

pH Probe

Probe Type Laboratory Grade
Detection Range 0~14
Temperature Range 5~60°C
Zero Point 7±0.5
Response Time <2min
Internal Resistance <250MΩ
Probe Life >0.5 year (depending on frequency of use)
Cable Length 100cm
This website follows the safe harbor principle. If any infringement, please inform us in time and we will delete it in time. About safe harbor,please click here to learn more.
...
After Sale Service:
1 Insurance Policy: Click to go to the Help Center to view the Insurance Policy
2 The rules apply and summit for receive compensation
3 The conditions of accrual for amount insurance
3 The conditions of accrual for amount insurance
5 Damage to the parcel during international shipping, which resulted in damage to the goods in it
6 Loss of individual goods under international shipment The absence individual goods in the parcel
7 Non-compliance individual goods in color, size, complications Damage to the goods during international shipment
8 Returns Policy: Click to go to the Help Center to view the Returns Policy
...
...
Gravity: Analog pH Sensor/Meter Kit V2 for Arduino - for Aquaponics Or Fish Tanks Or Other Materials That Need Measurements
Gravity: Analog pH Sensor/Meter Kit V2 for Arduino - for Aquaponics Or Fish Tanks Or Other Materials That Need Measurements

BEST SELLERS

...

Product Description

INTRODUCTION

  • DFRobot Gravity: Analog pH meter V2 is specifically designed to measure the pH of the solution and reflect the acidity or alkalinity.
  • It is commonly used in various applications such as aquaponics, aquaculture, and environmental water testing.

BACKGROUNDS

  • The pH is a value that measures the acidity or alkalinity of the solution. It is also called the hydrogen ion concentration index. The pH is a scale of hydrogen ion activity in solution. The pH has a wide range of uses in medicine, chemistry, and agriculture.
  • Usually, the pH is a number between 0 to 14. Under the thermodynamic standard conditions, pH=7, which means the solution is neutral; pH<7, which means the solution is acidic; pH>7, which means the solution is alkaline.

Gravity: Analog pH Sensor/Meter Kit V2

Gravity: Analog pH Sensor/Meter Kit V2

Attention

  1. The BNC connector and the signal conversion board must be kept dry and clean, otherwise, it will affect the input impedance, resulting in an inaccurate measurement. If it is damp, it needs to be dried.
  2. The signal conversion board cannot be directly placed on a wet or semiconductor surface, otherwise, it will affect the input impedance, resulting in the inaccurate measurement. It is recommended to use the nylon pillar to fix the signal conversion board, allow a certain distance between the signal conversion board and the surface.
  3. The sensitive glass bubble in the head of the pH probe should avoid touching with the hard material. Any damage or scratches will cause the electrode to fail.
  4. After completing the measurement, disconnect the pH probe from the signal conversion board. The pH probe should not be connected to the signal conversion board without the power supply for a long time.

SPECIFICATION-Signal Conversion Board (Transmitter) V2

Supply Voltage 3.3~5.5V
Output Voltage 0~3.0V
Probe Connector BNC
Signal Connector PH2.0-3P
Measurement Accuracy ±0.1@25℃
Dimension 42mm*32mm/1.66*1.26in

pH Probe

Probe Type Laboratory Grade
Detection Range 0~14
Temperature Range 5~60°C
Zero Point 7±0.5
Response Time <2min
Internal Resistance <250MΩ
Probe Life >0.5 year (depending on frequency of use)
Cable Length 100cm
Shipping Notices:
1 Contraband and limited items:
Clgarette,Alcohol,Contraband ?Do not accept
... ... ...
Liquid,cream or cosmetics items are quantity limited in shopping agent service
... ... ...
Chinese medicine is limited to ship by Chinese exporting goods.
...
2 Limitation for different shipping methods:
...
3 Yoybuy Product's Label:
...
Sensitive Product(SEN)
...
Product With battery
...
Cream
...
Powder
...
Dangerous Products
...
....
4 Volume weight Requested:
...
volume weight=length*height*Width/5000
...
one side must be less than 120cm,otherwise there is additional fee;250cm products can not be accept;
...
...
...
...
...
Any side must be less than 60cm,otherwise you will be charged the greater one between real weight and volume weight,more than 120cm will be not accepted.
After Sale Service:
2 The rules apply and summit for receive compensation
3 The conditions of accrual for amount insurance
3 The conditions of accrual for amount insurance
5 Damage to the parcel during international shipping, which resulted in damage to the goods in it
6 Loss of individual goods under international shipment The absence individual goods in the parcel
7 Non-compliance individual goods in color, size, complications Damage to the goods during international shipment
...

BEST SELLERS

Inquire Now
X

Contact us now

Language

Currency

    Upload image to find the same item

    Drag the image here, or Click to upload Tips: Only jpg, jpeg, png, webp

    Scan the QR code and use your phone to take a direct photo search.

    ×