Thermo Scientific Orion Glass Body ROSS Sure Flow Junction pH Electrode, with Waterproof Connector, 0 to 14 pH
Thermo Scientific Orion Glass Body ROSS Sure Flow Junction pH Electrode, with Waterproof Connector, 0 to 14 pH
  • Double-junction, combination electrode with glass body for use in high temperatures and corrosives
  • Free-flowing junction for use with dirty and viscous samples
  • Waterproof BNC connection with 1 m cable for reaching samples
  • Refillable for prolonging life of electrode
  • pH range is 0 to 14
Retail Price: $ 579.54
Wholesale Price: Inquire Now
This website follows the safe harbor principle. If any infringement, please inform us in time and we will delete it in time. About safe harbor,please click here to learn more.
...
After Sale Service:
1 Insurance Policy: Click to go to the Help Center to view the Insurance Policy
2 The rules apply and summit for receive compensation
3 The conditions of accrual for amount insurance
3 The conditions of accrual for amount insurance
5 Damage to the parcel during international shipping, which resulted in damage to the goods in it
6 Loss of individual goods under international shipment The absence individual goods in the parcel
7 Non-compliance individual goods in color, size, complications Damage to the goods during international shipment
8 Returns Policy: Click to go to the Help Center to view the Returns Policy
...
...
Thermo Scientific Orion Glass Body ROSS Sure Flow Junction pH Electrode, with Waterproof Connector, 0 to 14 pH
Thermo Scientific Orion Glass Body ROSS Sure Flow Junction pH Electrode, with Waterproof Connector, 0 to 14 pH

BEST SELLERS

...
The Thermo Scientific Orion 8172BNWP ROSS Sure Flow refillable, double-junction combination pH electrode has a glass body, a free-flowing junction for use with dirty and viscous samples, a waterproof Bayonet Neill-Concelman (BNC) connection with a 1 m (39") cable , and a 0 to 14 pH range. These electrodes are designed to allow the user to change the fill solution, depending on the sample requirements, and can be used on any pH meter with a BNC or U.S. standard connection. ROSS pH electrodes also have a patented internal reference to mimimize drift and equilibrium time. The double-junction reference system separates the sample from contact with silver ions, which means the electrode can be used with samples containing silver complexing or binding agents, such as tris (hydroxymethyl) aminomethane (TRIS or THAM), proteins, and sulfides. The electrode has a small hole, for refilling the the KCl fill solution, which prolongs the life of the electrode. Glass body electrodes are useful in highly corrosive environments where epoxy could be corroded, or around proteins and other compounds with high surface tension.This electrode can be used to test dirty and viscous samples because of the free-flow junction. The junction can be cleaned by pressing the cap down between measurements, which allows the filling solution to flow through the junction and clear contaminants.

The Thermo Scientific Orion 8172BNWP ROSS Sure Flow refillable, double-junction combination pH electrode has a glass body, a free-flowing junction for use with dirty and viscous samples, a waterproof Bayonet Neill-Concelman (BNC) connection with a 1 m (39") cable , and a 0 to 14 pH range. These electrodes are designed to allow the user to change the fill solution, depending on the sample requirements, and can be used on any pH meter with a BNC or U.S. standard connection. ROSS pH electrodes also have a patented internal reference to mimimize drift and equilibrium time. The double-junction reference system separates the sample from contact with silver ions, which means the electrode can be used with samples containing silver complexing or binding agents, such as tris (hydroxymethyl) aminomethane (TRIS or THAM), proteins, and sulfides. The electrode has a small hole, for refilling the the KCl fill solution, which prolongs the life of the electrode. Glass body electrodes are useful in highly corrosive environments where epoxy could be corroded, or around proteins and other compounds with high surface tension.This electrode can be used to test dirty and viscous samples because of the free-flow junction. The junction can be cleaned by pressing the cap down between measurements, which allows the filling solution to flow through the junction and clear contaminants.

pH range is 0 to 14 (+ or - 0.01), temperature range is 0 to 100 degrees C (+ or - 0.5), with 92 to 102% slope. Body dimensions are 120 (length) x 12 mm (diameter) and the electrode can measure samples as small as 0.2 mL. The electrode uses 3M KCl Orion 810007 fill solution. Buffer and storage solutions are sold separately.

pH electrodes are used in pH meters and testers to measure the acidity or alkalinity of a substance. They are often constructed of glass, which senses hydrogen ions, and generates a millivoltage that is picked up by the filling solution and transferred to a wire that connects to the pH meter.

Thermo Fisher Scientific manufactures analytical instruments, laboratory equipment, consumables, and software under the Thermo Scientific and Fisher Scientific brands, among others. The company was founded in 2006, and is headquartered in Waltham, MA.

What's in the Box?

  • Thermo Scientific Orion 8172BNWP pH electrode
  • Removable bulb guard
  • (2) 60 ml bottles fill solution, 810007
Shipping Notices:
1 Contraband and limited items:
Clgarette,Alcohol,Contraband ?Do not accept
... ... ...
Liquid,cream or cosmetics items are quantity limited in shopping agent service
... ... ...
Chinese medicine is limited to ship by Chinese exporting goods.
...
2 Limitation for different shipping methods:
...
3 Yoybuy Product's Label:
...
Sensitive Product(SEN)
...
Product With battery
...
Cream
...
Powder
...
Dangerous Products
...
....
4 Volume weight Requested:
...
volume weight=length*height*Width/5000
...
one side must be less than 120cm,otherwise there is additional fee;250cm products can not be accept;
...
...
...
...
...
Any side must be less than 60cm,otherwise you will be charged the greater one between real weight and volume weight,more than 120cm will be not accepted.
After Sale Service:
2 The rules apply and summit for receive compensation
3 The conditions of accrual for amount insurance
3 The conditions of accrual for amount insurance
5 Damage to the parcel during international shipping, which resulted in damage to the goods in it
6 Loss of individual goods under international shipment The absence individual goods in the parcel
7 Non-compliance individual goods in color, size, complications Damage to the goods during international shipment
...

BEST SELLERS

Inquire Now
X

Contact us now

Language

Currency

    Upload image to find the same item

    Drag the image here, or Click to upload Tips: Only jpg, jpeg, png, webp

    Scan the QR code and use your phone to take a direct photo search.

    ×